TNAG-1503-FCO40-2061-Guangdong-nuclear-power-station-project-at-Daya-Bay-safety-c-1986 — Page 163

FCO40 Hong Kong Department Records 聯邦事務部香港部檔案 All

SEP 02 86 16:42 TIB(00U) HK GOVT

177

PART V

P.3

1

1

5.1

According to

OBSERVATIONS

CHAPTER 1

GENERAL OBSERVATIONS

the information provided by the French, USA, Japanese and IAEA experts during the fact-finding trips, the following observations are made :-

(1)

the PWR type reactor, as is proposed for Daya Bay, is designed and will be constructed in such a way that even in the event of a worst accident

resulting in a core melt-down, the containment building will be able to contain most of the radioactive products; (Ref: 2.1.12; 4.2.15)

(2) the emergency planning required to be

prepare for a worst accident will be

3.1.12;

done to

of

(a) possible evacuation within a radius

10 Km, adopted in France and Japan, or 10 miles, as is required in USA; (Ref : 2.3.23; 3.4.7; 4.5.4)

(b) contingency actions on food and water

be taken within à radius of

of 50 Km (50 miles in USA)

USA) from the (Ref: 2.3.23; 3.4.7)

nuclear

plant;

Comments