B 38
[Subsidiary]
CAP. 295] Dangerous Goods (General) Regulations
[1983 Ed.
TABLE
Density at 15.5°C Filling Ratio
(D) (2)
0.495-0.499 0.385
0.500-0.504 0.390
0.505-0.509 0.395
0.510-0.514 0.400
0.515-0.519 0.410
0.520-0.524 0.415
0.525-0.529 0.420
0.530-0.534 0.425
0.535-0.539 0.435
0.540-0.544 0.440
0.545-0.549 0.445
0.550-0.554 0.455
0.555-0.559 0.460
0.560-0.564 0.465
0.565-0.569 0.475
0.570-0.574 0.480
0.575-0.579 0.485
0.580-0.584 0.490
0.585-0.589 0.500
0.590-0.594 0.505
0.595-0.600 0.510
Filling of cylinders containing dissolved gases.
L.N. 40/73. L.N. 119/83.
71. (1) No person shall fill any cylinder, or cause or permit any cylinder to be filled, with any dissolved gas unless—
(a) the cylinder is completely filled with a homogeneous porous substance of porosity not exceeding 88 per cent;
(b) without prejudice to sub-paragraph (a), if the cylinder contains a solvent, the solvent—
(i) is not of a kind capable of chemical reaction with the gas in the cylinder, the homogeneous porous substance or the metal of the cylinder; and
(ii) when the cylinder is fully charged, does not completely fill the porosity of the homogeneous porous substance at a temperature of 65°C.
(c) the tare weight is stamped in a conspicuous place on the outside of the cylinder;
(d) the cylinder valve contains not more than 70 per cent of copper in its composition;
B 38
[Subsidiary]
CAP. 295] Dangerous Goods (General) Regulations
[1983 Ed.
TABLE
Density at 15.5°C
Filling Ratio
(D)
(2)
0.495-0.499
0.385
0.500-0.504
0.390
0.505-0.509
0.395
:
0.510-0.514
0.400
0.515-0.519
0.410
0.520-0.524
0.415
0.525-0.529
0.420
0.530-0.534
0.425
0.535-0.539
0.435
0.540-0.544
0.440
0.545-0.549
0.445
0.550-0.554
0.455
0.555-0.559
0.460
0.560-0.564
0.465
0.565-0.569
0.475
0.570--0.574
0.480
0.575-0.579
0.485
0.580-0.584
0.490
0.585-0.589
0.500
0.590-0.594
0.505
0.595-0.600
0.510
Filling of cylin- ders containing dissolved gases.
L.N. 40/73. L.N. 119/83.
71. (1) No person shall fill any cylinder, or cause or permit any cylinder to be filled, with any dissolved unless-
gas
(a) the cylinder is completely filled with a homogeneous
porous substance of porosity not exceeding 88 per cent; (b) without prejudice to sub-paragraph (a), if the cylinder
contains a solvent, the solvent-
(i) is not of a kind capable of chemical reaction with the gas in the cylinder, the homogenous porous substance or the metal of the cylinder; and
(ii) when the cylinder is fully charged, does not com- pletely fill the porosity of the homogeneous porous sub- stance at a temperature of 65°C.
(c) the tare weight is stamped in a conspicuous place on the
outside of the cylinder;
(d) the cylinder valve contains not more than 70 per cent of
copper in its composition;