19m3
aterials within permitted limits to ensure that residents
protected from harm.
1.
This worst case scenario supposes a
burst in the primary loop pipes,
causing
coolant to spurt out and bringing about a
loss of water in the
reactor. If the
reactor core is damaged by
fire due to
loss
coolant, of
large a
amount of
radioactive
materials may
be released
into the containment building.
In this
event
the reactor
would perform
an
shut-down
and the
automatic emergency
multiple safety installations would carry
out their protective work.
are
2.
The drastic loss of
in
pressure
the primary loop would activate
the
water
injection safety
reservoir
of the
emergency
core
coolant system to open
the stop
valves and inject emergency
water
into the primary loop in order
to
make up for the coolant lost by the
system.
21
Page 135Page 136
h194པ།
15J810