Ships of Group 2:
Machinery
spaces contain-
ing internal
combustion
type machinery.
(e) a foam fire extinguishing installation complying with the
requirements of regulation 40;
Provided that if the engine and boiler rooms are not entirely separated from each other by a bulkhead, or if fuel oil can drain from the boiler room into the engine room, the combined engine and boiler rooms shall, for the purpose of this paragraph, be regarded as a single space.
(2) In addition to the requirement of paragraph (1) there shall be provided-
(0) in each boiler room one or more foam fire extinguishers each of at least 30 gallons capacity or carbon dioxide fire extinguishers each of at least 100 lb, capacity, so sited as to be readily accessible in the event of fire and sufficient in number to enable foam or carbon dioxide to be directed on to any part of the boiler room and spaces containing any part of the oil fuel installation:
(6) in each firing space and in cach space which contains any part of any oil fuel installation at least two portable fire extinguishers suitable for extinguishing oil fres; and
(c) in each firing space a receptacle containing at least 10 cubic feet of sand or other dry material suitable for quenching oil fires together with a scoop for its distribu- tion, or alternatively an additional portable fire extin- guisher suitable for quenching oil fires.
11. (1) In every ship of Group 2 there shall be provided for the protection of any space containing internal combustion type machinery used for main propulsion, or having in the aggregate a total power of not less than 1,000 b.h.p. for auxiliary purposes, at least one of the fixed fire extinguishing installations required by paragraph (1) of regulation 10.
(2) In addition to the requirements of paragraph (1) there shall be provided in any such space-
(a) one foam fire extinguisher of at least 10 gallons capacity or a carbon dioxide fire extinguisher of at least 35 lb. capacity; and
(b) one portable fire extinguisher suitable for extinguishing oil fires for cach 1,000 b.h.p. or part thereof of such machinery but in По event less than WO such extinguishers:
Provided that not more than six such extinguishers shall be required in any such space.
12. In every ship of Group 2 there shall be provided in spaces containing steam turbines or enclosed pressure lubricated steam engines used either for main propulsion, or having in the aggregate a total power of not less than 1,000 b.h.p. for auxiliary purposes- (a) foam fire extinguishers each of at least 10 gallons capacity or carbon dioxide fire extinguishers each of at least 35 lb. capacity sufficient in number to enable foam or carbon dioxide to be directed on to any part of the pressure lubrication system and on to any part of the casings en- closing pressure lubricated parts of the turbines, engines or associated gearing, if any:
Provided that such extinguishers shall not be required if equivalent protection is provided in such spaces by a fixed fire extinguishing installation fitted in compliance with paragraph (1) of regulation 10 or paragraph (1) of regulation 11; and
(b) one portable fire extinguisher for each 1,000 b.h.p. or part thereof of such machinery, suitable for extinguishing oil fires, but in no event less than two such extinguishers: Provided that-
(i) not more than six such extinguishers shall be required in any one such space; and
(ii) such extinguishers shall not be required in addition to any provided in compliance with paragraph (2) of regulation 11.
13. (1) Every ship of Group 2 sball carry one fireman's outfit for each 100 feet (or part thereof) of the registered length of the ship, but in no case less than two.
(2) Every such outfit required to be carried under paragraph (1) shall comply with the requirements of regulation 42 and at least two of them shall include breathing apparatus of the air hose type,
(3) If in any such ship which carries firemen's outfits con- taining only breathing apparatus of the air hose type an air hose exceeding 120 feet in length would be necessary to reach from the open deck well clear of any hatch or doorway to any part of the accommodation, service, cargo or machinery spaces, at least two sets of breathing apparatus of the self-contained type shall be provided in addition.
14. Every ship of Group 2 of 1,000 tons or over shall be provided with at least one international shore connexion which shall comply with the requirements of regulation 35 to enable water
2:
Ships of GroUP
Machinery spaces contain- ing steam engines.
Ships of Group
Firemen's
2:
outäts.
Ships of Group 2: Interua- tional shore connexion.