Towage of

vessels carrying indamma- ble liquid.

No other vessel to be towed together with a yeasel carrying dangerous goods of port

class E.

Dangerous

goods not

to be

carried

Logether

with

passengerH

Vessels

carrying dangerous Kooda of port class

A or E not.

permitted

in typhoon shelters.

Vessels carrying dangerous Koods of port class

A or E or intam- mable liquid not permitted

in dock, etc.

48

56. When any type VI vessel carrying highly inflammable or inflammable liquid is being towed-

(a) not more than four such vessels shall be towed together

at one time;

(6) not more than two such vessels shall be towed together

abreast;

(4) mot more than two such vessels shall be towed together

in single line; and

(4) no vessel of any other type, and no type VI vessel carrying any dangerous goods other than highly inflammable or inflammable liquids shall be towed together with such vessel.

59. When any type VI vessel carrying dangerous goods of port class E is being towed, no vessel of any other type and no type VI vessel carrying any other dangerous goods shall be lowed, together with such vessel.

60. No type VI vessel carrying any dangerous goods shall carry any passengers other than labourers employed to load or discharge the vessel,

61. No type VI vessel carrying any dangerous goods of port class A or E, or highly inflammable or inflammable liquids, shell be in the typhoon shelter at Yaumati or Causeway Bay,

62. No type VI vessel carrying any dangerous goods of port class A or E or any highly inflammable or inflammable liquid shall enter any dock or undergo in the Harbour repairs other than running repairs to machinery which do not involve the use of fires, blow-lamps, burners or naked lights, and which are undertaken after all holds have been closed down gastight.

A ur E.

63. Any type VI vessel which has loaded from another Loading of

dangerous vessel any dangerous goods of port class A or E or any highly goods of inflammable or inflammable liquid, shail as soon as such loading port class is completed leave the side of the discharging vessel and proceed directly either to a wharf or pier approved by the Director for the discharging of such dangerous goods or to a dangerous goods anchorage, and shall not move from such wharf, pier or anchorage until all dangerous goods have been discharged therefrom.

84. No type VI vessel carrying any dangerous goods of port Place of class A or E, or any highly inflammable or inflammable liquid when

shall-

(4) anchor or berth at any place other than-

berthing

carrying dangerous goods of port class

(1) alongside a vessel for the purpose of loading or A or E. discharging such dangerous goods; ur

(ii) at a wharf or pier approved for the loading or discharging of such dangerous goods; or

(iii) at a dangerous goods anchorage; or

(b) lie alongside any vessel between the times of sunset and

sunrise.

85. No fire, lights or electrical apparatus other than electric Fire etc. filament lamps or self-comained electric lamps, heaters, cookers not

permitted or other approved types of apparatus, so designed constructed on wharf and maintained as to be incapable of igniting inflammable during

loading or vapour, shall be used on any wharf at which highly inRammable discharg liquid is being loaded onto or discharged from any type VI vessel.

ing of highly inflamma ble liquid.

68. No iron or steel hammers or other instruments capable Iron or

aleel of causing a spark shall be used for the purpose of opening or hammere closing any hatch on any type VI vessel carrying inflammable not to be liquid.

67. No person shall wear any footwear having metal nails, studs, or other fittings liable to cause a spark, on board any type VI vessel carrying highly inflammable liquid.

1

used when carrying highly infiamman. ble liquid.

Studded not to be

footwear

worn when carrying highly infanuma- ble liquid.

Share This Page