10

(4).

No.2.4472/30, Reqn.No.251/1, to take such existing fittings

as may be required.

Two "Ross" Patent Muffled Pop Safety Valves of suitable

size are to be fitted.

The Regulator Valve is to be of the Lockyer Balanced type

as supplied by the A.B.C. Coupler & Engineering Co., Ltd.

The whistle stand, seat and whistles are to be the same

as shown on Drg. No. Z.4472/66, Regn.No. 251/1, and the

whistle arrangement is to be as shown on Drg. No.Z.4472/65,

Reqn. No. 251/1.

The glass gauge cocks, mechanical lubricator warming cock,

blow-off cock, pressure gauge cocks, pressure gauges, blower

valves etc. are to be the same as shown on Drg.No.Z.4472/67,

Reqn. No.251/1. The water gauges are to be mounted in such

a position that with the water level 5" above the highest

point of the crown sheet, glass of water is shown in the

gauge.

12. Firedoor and Gear. The Franklin automatic firedoor, butterfly

type No. 8 right-hand, manufactured by the Franklin Railway Supply Co., New York, and as shown on Drg.No.2.4472/22, Regn.

No. 251/1, is to be fitted on these engines.

13. Tubes and Flues. The boilers are to be fitted with solid

drawn steel tubes, 2a outside diameter x 11 W.G. thick and

solid drawn steel flues 54" dia. x 8 W.G. thick, of approved

manufacture.

The tubes are to be beaded over at the firebox tube plate,

steel ferrules are not required. The flues are to be grooved

at the firebox end, expanded into the copper tube plate and

beaded over. In the smokebox, the tubes are to be left

projecting 4" and the flues 3/8".