44
fire-place and an
inlet and outlet flue
12 inches by 9 inches and the adjoining
will contain a bath, closet and sink
lobby will contain
ventilated and trapped
way
Floor
as the others.
in the same
As the arrangements of the second
are--
identical with the first further explanation is necessary beyond calling attention to the proposal to mail. the eciling immediately to the principal rafters, leaving the trusses of the roof exposed to view. This will considerably increase the cubic space of the Wards __ and the sloping ceiling
leading up
on either side
to the open louvred ventilator
running along the middle will greatly facilitate the extraction of foul air.
The roof principals will be oiled and rubbed and the ceiling of hardwood boards will be
blue. painted light grey
To raise patients
to the upper floors it is
suggested to have a mechanical counterbalance lift at the East end of the Back Verandah, the traffie not being large
enough
on
to warrant a
hydraulie
one.
eAt the Western end of the Back Verandah
both floors will be the Ward Seulleries with cemented walls and ceilings, marble floor, ventilating windows at right angles to-one another and with inlet and outlet flues on the same
principle bold water will be laid on to the sinks of which there will be two in each scullery,
one a
as the wards.
Jenning's slop sink with lever handle