Supply of T.W. cistern and cushion intermediate feed cistern 16" x 9" x 18" with mica ball valve and mica 10.1" feed pipe connected into return pipe.
4. Circulating pipes.
1 1/4" W.I. circulating pipe, connecting the boiler and hot water cistern, the return pipe being carried under the secondary flue to the bath tower and back.
1/2" W.I. flow and return pipe, to be carried from the boiler under the corridor floor to the sword blacksmith's workshop and boiler house. 1/4" flow and return pipe to the bath tower and blacksmith's workshop.
All the pipes to be laid to regular fall, to facilitate circulation and to be supported under the concrete floor on proper brackets and hangers. The circulating pipes to be well clothed with felt and covered with two coats of ...
6. Laying on. Animal supply cock with stop valve, with inch draw off pipes for emptying boiler. Hot water services from the circulating pipe to the different bath rooms and bath tubs, with proper Ts and connections and services to dispensary branch of the lavatories and to scullery sinks.
Woodwork
A. Jaw half-inch form metal bib cocks screwed for half-inch pipe with stop valves and branches to lavatories and 3/4" cocks and shutters to sinks. Track metal bib cocks screwed with four-way pipes, with wood-covered handles, for hot water to each bath and to bath tubs.
6. Generally, All the W.I. Pipes to be equal to steam, put together with un-leakage joint and red and white lead, with all necessary Ts, bends, elbows, long screws, back nuts, etc.
Lift.
Provide and fix a hand-power lift with inside dimensions: The lift to be 3'6" high and 2'0" x 2'0" fitted with shallow sliding tray and lift. The height through which the lift travels is ... (Overlayed detail drawing should be prepared to show exact space available).