1984 Ed.]
Building (Planning) Regulations
[CAP. 123
F 29
[Subsidiary]
FIRST SCHEDULE
PERCENTAGE SITE COVERAGES AND PLOT RATIOS
[regs. 20 & 21.]
L.N. 294/76.
Domestic buildings Percentage site coverage Plot ratio Height of building in metres Class A site Class B site Class C site Class A site Class B site Class C site Not exceeding 15 m 66.6 75 80 3.3 3.75 4.0 Over 15 m but not exceeding 18 m 60 67 72 3.6 4.0 4.3 Over 18 m but not exceeding 21 m 56 62 67 3.9 4.3 4.7 Over 21 m but not exceeding 24 m 52 58 63 4.3 4.6 5.0 Over 24 m but not exceeding 27 m 49 55 59 4.4 4.9 5.3 Over 27 m but not exceeding 30 m 46 52 56 4.6 5.3 5.5 Over 30 m but not exceeding 36 m 41 47.3 50 5.0 5.7 6.0 Over 36 m but not exceeding 43 m 38 44 47 5.4 6.1 6.5 Over 43 m but not exceeding 49 m 37 41 44 5.9 6.3 7.0 Over 49 m but not exceeding 55 m 35 39 42 6.3 7.0 7.5 Over 55 m but not exceeding 61 m 34 38 41 6.8 7.6 8.0 Over 61 m 33.33 37.5 40 8.0 9.0 10.0 Non-domestic buildings Percentage site coverage Plot ratio Height of building in metres Class A site Class B site Class C site Class A site Class B site Class C site Not exceeding 15 m 100 100 100 5 5 5 Over 15 m but not exceeding 18 m 97.5 97.5 97.3 5.8 5.8 5.8 Over 18 m but not exceeding 21 m 95 95 95 6.7 6.7 6.7 Over 21 m but not exceeding 24 m 92 97 92 7.4 7.4 7.4 Over 24 m but not exceeding 27 m 90 90 90 8.0 8.1 8.1 Over 27 m but not exceeding 30 m 85 87 87 8.5 8.7 8.8 Over 30 m but not exceeding 36 m 80 82.5 85 9.0 9.5 10.2 Over 36 m but not exceeding 43 m 77.5 80 80 10.3 10.8 11.3 Over 43 m but not exceeding 49 m 69 72.5 73 11.6 12.0 12.0 Over 49 m but not exceeding 55 m 64 67.5 70 11.5 13.1 12.6 Over 55 m but not exceeding 61 m 60 62.5 63 13.0 12.5 13.0 Over 61 m 60 62.5 65 13 15 15SECOND SCHEDULE
OPEN SPACE ABOUT DOMESTIC BUILDINGS
Item
Class of site
Open space required
[reg. 25.]
G.N.A. 97/62. L.N. 82/63.
1. Class A site. Not less than one-half of the roofed-over area of the building. 2. Class B site. Not less than one-third of the roofed-over area of the building. 3. Class C site. Not less than one-quarter of the roofed-over area of the building.THIRD SCHEDULE
DISABLED PERSONS
[reg. 72.]
L.N. 365/84.
(In operation on 1.8.85)
PART I
Initial Access
1.
(1) Access shall be provided from a point or points on the lot boundary to at least one entrance and to a lift complying with item 4.