Values of

10

1985 Ed.]

Long span coefficients

B1 for

all values

Building (Construction) Regulations

Type of panel and

moments considered

2 3 S 6 7 8 9 of 2.0 1.0 1.1 1.2 1.3 1.4 1.5 1.75 or more [CAP. 123 Interior panels negative moment at continuous edge 0.033 0.040 0.045 0.050 0.054 0.059 0.071 0.083 0.033 positive moment at mid-span 0.025 0.030 0.034 0.038 0.041 0.045 0.053 0.062 0.025 2. I short or long edge is discontinuous- L.N. 42/75. negative moment at continuous edge 0.041 0.047 0.053 0.057 0.061 0.065 0.075 0.085 0.041 positive moment at mid-span 0.031 0.035 0.040 0.043 0.046 0.049 0.056 0.064 0.031 3. 2 adjacent edges discontinuous- negative moment at continuous edge 0.049 0.056 0.062 0.066 0.070 0.073 0.082 0.090 0.049 positive moment at mid-span 0.037 0.042 0.047 0.050 0.053 0.055 0.062 0.068 0.037

B 85

[Subsidiary]

Page 85




Page 86

Page 86

Page 86

Share This Page