B 20

CAP. 123]

Building (Construction) Regulations

[1985 Ed.

[Subsidiary]

L.N. 294/76.

(c) the imposed loads to be provided for types of floors, roofs, stairs and landings and corridors and cantilever steps not mentioned in Table VII shall be ascertained to the satisfaction of the Building Authority.

TABLE VII

Minimum imposed loads (not including induced wind loads)

3

4

Slabs

KN

Beams

KN

Class

kPa floors.

No.

Types of floors, roofs, stairs etc.

roofs, etc.

1

Floors for domestic buildings of not more than 2 storeys, in occupation: dormitories: hospital wards. bedrooms, toilet rooms; hotel (and motel) private sitting rooms. bedrooms. toilet rooms

2

Floors for domestic buildings (other than those of class No. 1): hospital dining-rooms, operating theatres. consulting rooms. X-ray rooms (Equipment to be determined, but not less than): workrooms, light, without central power driven machines and storage

Floors for college and school classrooms, lecture theatres: college and school laboratories (equipment to be determined, but not less than): offices above the entrance floor

Floors for assembly areas with fixed seating: banking halls; chapels, churches and places of worship (with fixed seating); garages for vehicles not exceeding 2.4 tonnes gross weight; kitchens other than in domestic buildings (equipment to be determined, but not less than); laundries other than in domestic buildings (equipment to be determined, but not less than): office entrance floors and office floors below the entrance floor: retail shops for display and sale of merchandise: workrooms with central power driven machines

uniformly distributed over the span per metre width

uniformly distributed over span

2.0

4.7

11.5

2.5

6.0

14.3

3.0

7.0

17.0

4.0

9.5

22.8