THE HONG KONG GOVERNMENT GAZETTE, AUGUST 3, 1934.

66. The lighting points shall be so arranged that all parts Recesses, of the premises, including recesses and cupboards, can be cupboards, adequately illuminated.

etc.

67. If the installation of oil or candle lamps be permitted oil or by the Licensing Authority, the lamps shall be of a pattern candle lamps. approved by the Licensing Authority, and shall be properly fixed away from woodwork or other combustible materials and where practicable they shall be out of reach of the public. Lamps for burning kerosene or other mineral oil shall not be provided.

68. Provision shall be made so that each notice indicating Lighting of an exit may be illuminated by a light on each system. In the exit notices. auditorium of a theatre, music hall or in such other places or positions as the Licensing Authority may determine, provi- sion shall be made so that such notice may be internally illuminated by a light on at least one of the systems.

exit notices,

69. The lighting to exit notices shall not in any circum Lighting of stances be extinguished or dimmed while the public are on the premises.

70. Notices, other than exit notices in or about the Notices in auditorium or main hall, shall not be internally illuminated.

auditorium.

exits.

71. Corridors and staircases which form the means of es- Lighting of cape from any stage or platform or from any dressing or retir- stage, etc., ing rooms, and the notices indicating the exits from such portions of the premises shall be provided with two independent systems of lighting to the satisfaction of the Licensing Authority. Provided that, in the case of small premises, two independent systems of lighting need not be provided if the Licensing Authority is satisfied that two systems are not necess- ary in those portions of the premises.

72. Gas, oil or candle lamps shall not be installed within Gas, oil, the limits of the stage or platform or in positions in which it is etc., lamps. possible for them to come into contact with scenery or pro- perties.

73.-(1) Lamp shades of readily combustible material Lamp shall not be provided.

(2) Lamp shades shall be of incombustible material except when intended for use in positions remote from combustible materials. If shades of combustible material be provided for use in such positions, they shall be rendered satisfactorily non- inflammable, shall be suitably ventilated to the satisfaction of the Licencing Authority and shall be so arranged that, in case of electric lighting fittings, it will not be possible for the shades to come into contact with the lamp or holder, and, in the case of gas fittings, the shades are efficiently protected from the flame or from any parts of the fitting liable to reach a high temperature. No shade of a large size or elaborate nature shall be provided without the previous consent of the Licensing Authority.

shades,

enclosure.

74.-(1) The main switches, meters and other electrical Electrical apparatus in connection with the intake from the supply under- intake taking shall be installed in an enclosure. The enclosure shall be in a dry position, shall be of adequate size, shall be con- structed of fire-resisting materials, and shall be adequately ventilated.

591