SCHEDULE OF REQUIREMENTS

POST: CONSULATE - GENERAL HONG KONG

SCHEME: NEW OFFICES

DATE: JANUARY 1994

SECTION

OFFICER OR

NO

GRADE

FUNCTION

OF

CLASSI- FICATION

NETT

AREA

STAFF

M2

(1)

(2)

(39)

Main reception and

enquiry point

(40)

Public

reception

area

(3)

(4)

(5)

(6)

LEIVS

U/C

17.0

U/C

65.0

(41)

Agency counter

drop

U/C

7.5

(42)

Cashier/Visa

U/C

15.0

Collection

Counters

(43)

Secondary waiting

U/C

60:0

area

(44)

$

Primary Interview Booths/Counters

(at 60 ft2 each)

9.6

U/C

36.0

REMARKS

(7)

Staffed from (33). Provide B/R glass counters with 2 speech units and document passing facilities into (40).

Provide cooled drinking water, writing and queuing facilities adequate for 100 standing. Provide if possible separate exit. Provide air lock access

to main offices controlled from (39). Doors of airlock should interlock to allow only one door to be open at a time.

Locate near to entrance to (40). Provide B/R glass counters with speech unit and document passing facilities into (40) staffed from (33). Staffed from 33. Provide B/R glass counters, 2 speech units and document passing facilities into both (40) and (43).

access

via (40)

Adequate for 50 seated: controlled by (42). Provide cooled drinking water writing and seating facilities. Provide separate exit from building and turnstile re entry to (40). Latter only necessary if public toilets located in (40).

to

Each booth to have speech unit and B/R screen to counter level and be lined with sound deadening material. Booths to be large enough accommodate 2 people on each side plus VDU on staff side. Public to have access from (43). But divided from (43) by a barrier/screen (ceiling height size) which should be translucent but not transparent. Interconnect with (33) by means of door(s) and hatch(es). Good lighting required. Provide controlled access and exit between 144 and L43.

Public access by controlled door via (43). Divide room by B/R screen.

Provide speech facilities.

(45)

3

Secondary

Interview

(at 100ft2 each)

Unterlies ndod

U/C

27.0

rooms

ma

Publie access by controlled doorxia (437 Open Alan-byt divide by wide desk wall to well-with bar flap. The door to staff circulation should |{{be fitted with PBCL .

(47)

Machine room

U/C

11.0

(48)

Stationery Store

U/C

14.0

HONGKONG.SOR

580

[-126]

Page 15Page 16