SCHEDULE OF REQUIREMENTS

POST: CONSULATE-GENERAL HONG KONG

SCHEME: NEW OFFICES

DATA: DECEMBER 1991

SECTION

OFFICER OR

NO

GRADE

FUNCTION

OF

CLASSI- FICATION

NETT AREA

REMARKS

STAFF

(1)

(2)

(3)

(4)

(5)

(6)

(7)

H.

GATEHOUSE

(1)

Security 1-2

Contract

U/C

120

Reception/

Guardroom

(2)

Site Pedestrian

Entrance

(3)

Search Room

(4)

Guard's WC

(5)

Vehicle Inspection

Lock

I.

(1)

U/C

120

As

necessary

Specifications are concrete walls with B/R glass to give vision all round and into entrance area and vehicle inspection lock. Provide 2 speech units and document passing facilities.

Adjacent to guard room with secure screens to front and rear, each with electronic controlled pedestrian gate. Provide space for metal arch detection unit and wand search area. Bell push externally to guard room.

Access off 2.

Provide WHB

Solid heavy duty manual double gate to secure perimeter with spyhole, lockable internally leading onto barriered section of access road immediately inside gate sufficient to hold a single small truck. Internally provide a manually operated lift-up anti-crash barrier.

U/C

50

U/C

30

U/C

STORE ROOMS (TO BE LOCATED IN BASEMENT, IF POSSIBLE, UNLESS INDICATED OTHERWISE WITH EASY VEHICLE AREA)

U/C

150

If suitable space available can also be located in or near to section F.

Domestic equipment

(2)

Stationery

(3)

Furniture and

General

U/C

500

11

U/C

1000

J. MISCELLANEOUS

(1)

Dedicated Computer

U/C

220

гоом

(2)

Interview meeting

U/C

200

room

(3)

First

гоом

Aid/Sick

U/C

130

(4)

Smoking Area

U/C

150

(5)

Conference room

U/C

550

HONGKONG.SOR

"

If additional space required either locate in any surplus basement space or outhouse in warehouse.

Locate centrally in U/C area and if possible within or near to section F and in particular F(13). Provide 24 hr A/C.

For use of all sections. Locate adjacent to G4 to give access from G(4) and to staff areas. Door from g(4) to be controlled from G(2)/(3) by an electronic lock. The door to staff circulation should be fitted with a PBCL.

Provide sink and locate near to WC facilities.

Locate adjacent and with public access direct from D(10) if possible. Interconnect to J(6) by sliding type doors to create large area for receptions etc.