3.

Measurement Procedures

3.1 Assessment Point

12

determined by carrying out

Noise levels at the NSR shall be

measurements at the assessment point. The assessment point shall be

at a position 1 m from the exterior of the building facade of the

NSR, at a particular point considered appropriate by the Authority.

Where a measurement is to be made of noise being received at a NSR

which is not a building, the assessment point shall be at a position

1.2 m above the ground, at a particular point considered appropriate

by the Authority.

Where the noise under investigation is being received within a

building from a noise source located on or within the same or an

adjoining building such that the noise is transmitted primarily

through the structural elements of the building or buildings, the

internal assessment point shall be at a particular location which

the Authority considers appropriate having regard to the normal

occupancy of the building.

3.2 Noise Units and Descriptors

Any noise measurement to determine the MNL shall be made in terms of

the A-weighted equivalent continuous. sound pressure level (Leq)

measured with an integrating sound level meter set

to the "fast"

response. Such measurement shall be made over any 30 minute period,

which shall be taken to be the STP.

3.3 Rounding of Noise Levels

With the exception of the CNL which should be calculated to the

whole dB(A), with values of 0.5 or more being rounded

nearest

upwards, other measured or calculated

determined to the nearest 0.1 dB(A) or dB,

more being rounded upwards.

be

noise levels shall

with values of 0.05 or

3.4 Weather Conditions

Noise measurements should not be made in the

wind with a steady speed exceeding 5 m/s,

exceeding 10 m/s.

presence of fog,rain,

or wind with gusts

Share This Page