2

Standard acoustical terminology is used throughout this Technical

Other terms are as defined in the Ordinance or in the.

Memorandum.

text of this Technical Memorandum.

1.4 General Introduction to the Procedures

When investigating a complaint regarding noise emanating from places or premises falling within the scope of this Technical Memorandum

the Authority shall generally act in accordance with the following

procedures which are detailed in subsequent sections. The Authority

shall:-

(a) determine the appropriate Acceptable Noise Level for the Noise

Sensitive Receiver in question (in accordance with Section 2);

(b) conduct measurements to obtain the Corrected Noise Level of the

noise under investigation (in accordance with Section 3); and

(c) compare the Corrected Noise Level with the Acceptable Noise

Level to determine if a Noise Abatement Notice may be issued

(in accordance with Section 4).

2.

DETERMINATION OF THE ACCEPTABLE NOISE LEVEL

2.1 General

The appropriate Acceptable Noise Level (ANL) for a particular Noise Sensitive Receiver (NSR) is dependent upon the character of the area

within which the NSR is located, and the time of day under

consideration.

"ཐ

The steps to be followed in determining an ANL are as follows :-

(a) identify the NSR, in accordance with Section 2.2;

(b)

(c)

determine the Area Sensitivity Rating (ASR) of the area within which the NSR is located, in accordance with Section 2.3; and

determine the ANL from the appropriate table in Section 2.4, by reference to the ASR and the time period under consideration.