3.

Measurement Procedures

3.1 Assessment Point

Noise

Where a measurement

levels shall be determined by carrying out measurements at the

assessment point.

is to be carried out at a

building, the assessment point shall be at a position 1m from the

exterior of the building facade, at a particular point considered

appropriate by the Authority. Where a measurement is to be made of

noise being received at a place other than a building, the assessment point shall be at a position 1.2m above the ground, at a particular point considered appropriate by the Authority.

3.2 Noise Units and Descriptors

Noise measurement shall generally be made in terms of either the

equivalent continuous sound pressure level (Leq), measured over any 5 minute period with an integrating sound level meter, or in terms of the

maximum noise level. Measurements shall be made in units of the

A-weighted decibel with the sound level meter set to "fast" response.

3.3 Rounding of Noise Levels

All noise measurements shall be rounded to the nearest whole dB(A), with values of 0.5 or more being rounded upwards.

3.4 Weather Conditions

rain,

Noise measurements should not be made in the presence of fog, wind with a steady speed exceeding 5 m/s, or wind with gusts exceeding

10 m/s.