G.F. 323

0003230

CONFIDENTIAL

21

-

(c) For any transmitter the maximum level of

any harmonic generated shall be at least 60dB

below the peak envelope power, developed with

the vision transmitter operating at full power

and the sound transmitter operating at maximum

deviation, and shall not exceed a power of

25 microvolts.

(a)

Sub-harmonic and combination frequencies

generated within the transmitting equipment

shall not have amplitudes greater than 1

microwatt.

(e) When any transmitter is operated at full

power into an adequately screened test band,

the field strength at a distance of one metre

shall not exceed 100 mV/m.

(f) The level of RF power present in the

power lines or control cables to a transmitter

shall be maintained below the minimum liable

to cause any disturbing influence to other

equipment in the transmitter station.

CONFIDENTIAL &

機密