This section has also commissioned 228 perimeter lights, taxiway lights, obstruction lights and apron floodlights at the Apron Extension Area and 8 conveyorized benches in the Passenger Terminal Building for Customs inspection of incoming passenger baggage.
8.47 The Lion Rock Tunnel Electrical and Mechanical Service Section operates and maintains all mechanical and electrical systems and electronic equipment connected with the toll booths and recorders, carbon monoxide monitoring, visibility indication and alarms, height detection, emergency communications, fire extinguisher alarms, traffic aid and signal control, tunnel lighting, ventilation plants and 'no-break' generating sets as well as flashing lane marker beacons at both southern and northern ends of the toll plaza. 727 repairs were carried out and 1,687 tunnel lights replaced during the year. In addition, the section carried out the general overhaul and maintenance of toll registration equipment and treadle system in Lane 1 to Lane 7, classification indicators in toll booths, supply and exhaust fan induction motors, contactor timers and air flow pressure equipment in the Kowloon and Sha Tin fan houses, visibility indication alarm units and control equipment in the tunnel and the Sha Tin no-break generating set and the control cubicle in the Sha Tin fan house. The height detector equipment was repositioned.
8.48 The Hospital Services Section is responsible for the operation and maintenance of diverse plant and equipment by means of which the services in all Government and Military Hospitals are provided. The steam, hot water, air-conditioning, mechanical and electrical services have been maintained in all hospitals throughout the year with no unscheduled stoppages and no major breakdown of plant or equipment. With the installation of a bulk liquid oxygen storage tank at Queen Mary Hospital the limitations imposed by the single cylinder battery system previously used have been overcome. In Queen Elizabeth Hospital new equipment such as a Rapid Cooling Fluid Autoclave and a Combi-Folder, installed in the Pharmacy and Laundry Departments respectively, has been added to the routine servicing and maintenance schedules. A total of 7,853 mechanical, 16,227 electrical and 1,127 air-conditioning repairs were carried out. In addition 1,564 items of hospital equipment were overhauled.
¡
This section has also commissioned 228 perimeter lights, taxiway lights, obstruction lights and apron floodlights at the Apron Extension Area and 8 conveyorized benches in the Passenger Terminal Building for Customs inspection of incoming passenger baggage.
Lion Rock Tunnel
8.47 The Lion Rock Tunnel Electrical and Mechanical Service Section operates and maintains all mechanical and electrical systems and electronic equipment connected with the toll booths and recorders, carbon monoxide monitoring, visibility indication and alarms, height detection, emergency communications, fire extinguisher alarms, traffic aid and signal control, tunnel lighting, ventilation plants and 'no-break' generating sets as well as flashing lane marker beacons at both southern and northern ends of the toll plaza. 727 repairs were carried out and 1,687 tunnel lights replaced during the year. In addition, the section carried out the general overhaul and maintenance of toll registration equipment and treadle system in Lane 1 to Lane 7, classification indicators in toll booths, supply and exhaust fan induction motors, contactor timers and air flow pressure equipment in the Kowloon and Sha Tin fan houses, visibility indication alarm units and control equip- ment on the tunnel and the Sha Tin no-break generating set and the control cubicle in the Sha Tin fan house. The height detector equip- ment was repositioned.
Hospital Services
8.48 The Hospital Services Section is responsible for the operation and maintenance of diverse plant and equipment by means of which the services in all Government and Military Hospitals are provided. The steam, hot water, air-conditioning, mechanical and electrical services have been maintained in all hospitals throughout the year with no unscheduled stoppages and no major breakdown of plant or equipment. With the installation of a bulk liquid oxygen storage tank at Queen Mary Hospital the limitations imposed by the single cylinder battery system previously used have been overcome. In Queen Elizabeth Hospital new equipment such as a Rapid Cooling Fluid Autoclave and a Combi-Folder, installed in the Pharmacy and Laundry Depart- ments respectively, has been added to the routine servicing and main- tenance schedules. A total of 7,853 mechanical, 16,227 electrical and 1,127 air-conditioning repairs were carried out. In addition 1,564 items of hospital equipment were overhauled.
107
No comments yet.
Private notes are available after approval.