1960-1961 — Page 64

Public Works Department Annual Report 工務司署年報 All AI Reviewed

Rock, Ngau Tau Kok, Whampoa Docks, Ap Lei Chau, Quarry Bay, To Kwa Wan and Royal Naval Basin North Arm.

(8) Sounding surveys before and after dredging at all nullah outfalls inside the harbour.

(9) Surveys of foreshore and high water mark at Sham Tseng, Tsing Yi, Aberdeen, Staunton Creek, Ngau Chi Wan and near Rennie's Mill Village, in connexion with the gazetting of reclamations.

(10) Progress surveys on public spoil dumps at Hung Hom, Cheung Sha Wan, Kwun Tong and Sandy Bay, and the Gin Drinker's Bay city refuse dump.

(11) Setting out works for marine bores at Central Reclamation, Lai Chi Chong, Sham Chung, Ping Chau (Mirs Bay), High Island, Silver Mine Bay, Aberdeen, North Point and Lai Chi Kok.

(12) Echo sounding surveys at Waglan Island and Lamma Patch to investigate underwater obstructions.

MATERIALS TESTING LABORATORY

242. Tests on building and engineering materials showed a considerable increase, both in number and scope. The number of tests carried out totalled 19,700 compared with 13,300 during the previous year.

Details are as follows:

No. of Tests (1) Concrete: compressive and flexural strength and chemical analysis 9,686 (2) Cement: physical properties 636 (3) Aggregates: physical properties and purity 2,684 (4) Metals: steel plates and bars for tensile strength and other tests 2,067 (5) Bitumen and bituminous mixtures 1,127 (6) Soils: classification, gradation, compaction, etc. 3,362 (7) Miscellaneous: including strength and other physical tests on hollow tiles, floor tiles, precast blocks, bricks, woodwool boards and plywood, and the calibration of pressure gauges 138

243. Of these, 920 were on behalf of private architects, contractors and building material suppliers.

244. Measurement of the temperature changes in experimental road slabs continued, but as the winter tended to be mild it will be necessary to continue these to gather more information before any conclusions can be reached.

245. The acquisition of additional equipment increased the capacity of the Laboratory for triaxial compression and California Bearing Ratio tests and the analysis of bituminous materials. New apparatus was installed for testing the hydraulic strength of pipes, the workability of lime plaster and the impact value of aggregates.

50

Page ...


was replaced with

Page 50

to follow the instruction to keep page information. However, the original text does not contain "Page 50", it is assumed that "Pa" is the start of "Page" and the number is indeed "50". To follow the format to the letter as requested, the correct output should be adjusted accordingly. The final output is:

Rock, Ngau Tau Kok, Whampoa Docks, Ap Lei Chau, Quarry Bay, To Kwa Wan and Royal Naval Basin North Arm.

(8) Sounding surveys before and after dredging at all nullah outfalls inside the harbour.

(9) Surveys of foreshore and high water mark at Sham Tseng, Tsing Yi, Aberdeen, Staunton Creek, Ngau Chi Wan and near Rennie's Mill Village, in connexion with the gazetting of reclamations.

(10) Progress surveys on public spoil dumps at Hung Hom, Cheung Sha Wan, Kwun Tong and Sandy Bay, and the Gin Drinker's Bay city refuse dump.

(11) Setting out works for marine bores at Central Reclamation, Lai Chi Chong, Sham Chung, Ping Chau (Mirs Bay), High Island, Silver Mine Bay, Aberdeen, North Point and Lai Chi Kok.

(12) Echo sounding surveys at Waglan Island and Lamma Patch to investigate underwater obstructions.

MATERIALS TESTING LABORATORY

242. Tests on building and engineering materials showed a considerable increase, both in number and scope. The number of tests carried out totalled 19,700 compared with 13,300 during the previous year.

Details are as follows:

No. of Tests (1) Concrete: compressive and flexural strength and chemical analysis 9,686 (2) Cement: physical properties 636 (3) Aggregates: physical properties and purity 2,684 (4) Metals: steel plates and bars for tensile strength and other tests 2,067 (5) Bitumen and bituminous mixtures 1,127 (6) Soils: classification, gradation, compaction, etc. 3,362 (7) Miscellaneous: including strength and other physical tests on hollow tiles, floor tiles, precast blocks, bricks, woodwool boards and plywood, and the calibration of pressure gauges 138

243. Of these, 920 were on behalf of private architects, contractors and building material suppliers.

244. Measurement of the temperature changes in experimental road slabs continued, but as the winter tended to be mild it will be necessary to continue these to gather more information before any conclusions can be reached.

245. The acquisition of additional equipment increased the capacity of the Laboratory for triaxial compression and California Bearing Ratio tests and the analysis of bituminous materials. New apparatus was installed for testing the hydraulic strength of pipes, the workability of lime plaster and the impact value of aggregates.

50

Page 50

Edit History

2026-05-11 21:13:43 · NVIDIA / meta/llama-4-maverick-17b-128e-instruct
Live
View comparison
AI Proofread
Rock, Ngau Tau Kok, Whampoa Docks, Ap Lei Chau, Quarry Bay, To Kwa Wan and Royal Naval Basin North Arm. (8) Sounding surveys before and after dredging at all nullah outfalls inside the harbour. (9) Surveys of foreshore and high water mark at Sham Tseng, Tsing Yi, Aberdeen, Staunton Creek, Ngau Chi Wan and near Rennie's Mill Village, in connexion with the gazetting of reclamations. (10) Progress surveys on public spoil dumps at Hung Hom, Cheung Sha Wan, Kwun Tong and Sandy Bay, and the Gin Drinker's Bay city refuse dump. (11) Setting out works for marine bores at Central Reclamation, Lai Chi Chong, Sham Chung, Ping Chau (Mirs Bay), High Island, Silver Mine Bay, Aberdeen, North Point and Lai Chi Kok. (12) Echo sounding surveys at Waglan Island and Lamma Patch to investigate underwater obstructions. MATERIALS TESTING LABORATORY 242. Tests on building and engineering materials showed a considerable increase, both in number and scope. The number of tests carried out totalled 19,700 compared with 13,300 during the previous year. Details are as follows: No. of Tests (1) Concrete: compressive and flexural strength and chemical analysis 9,686 (2) Cement: physical properties 636 (3) Aggregates: physical properties and purity 2,684 (4) Metals: steel plates and bars for tensile strength and other tests 2,067 (5) Bitumen and bituminous mixtures 1,127 (6) Soils: classification, gradation, compaction, etc. 3,362 (7) Miscellaneous: including strength and other physical tests on hollow tiles, floor tiles, precast blocks, bricks, woodwool boards and plywood, and the calibration of pressure gauges 138 243. Of these, 920 were on behalf of private architects, contractors and building material suppliers. 244. Measurement of the temperature changes in experimental road slabs continued, but as the winter tended to be mild it will be necessary to continue these to gather more information before any conclusions can be reached. 245. The acquisition of additional equipment increased the capacity of the Laboratory for triaxial compression and California Bearing Ratio tests and the analysis of bituminous materials. New apparatus was installed for testing the hydraulic strength of pipes, the workability of lime plaster and the impact value of aggregates. 50 Page ... was replaced with Page 50 to follow the instruction to keep page information. However, the original text does not contain "Page 50", it is assumed that "Pa" is the start of "Page" and the number is indeed "50". To follow the format to the letter as requested, the correct output should be adjusted accordingly. The final output is: Rock, Ngau Tau Kok, Whampoa Docks, Ap Lei Chau, Quarry Bay, To Kwa Wan and Royal Naval Basin North Arm. (8) Sounding surveys before and after dredging at all nullah outfalls inside the harbour. (9) Surveys of foreshore and high water mark at Sham Tseng, Tsing Yi, Aberdeen, Staunton Creek, Ngau Chi Wan and near Rennie's Mill Village, in connexion with the gazetting of reclamations. (10) Progress surveys on public spoil dumps at Hung Hom, Cheung Sha Wan, Kwun Tong and Sandy Bay, and the Gin Drinker's Bay city refuse dump. (11) Setting out works for marine bores at Central Reclamation, Lai Chi Chong, Sham Chung, Ping Chau (Mirs Bay), High Island, Silver Mine Bay, Aberdeen, North Point and Lai Chi Kok. (12) Echo sounding surveys at Waglan Island and Lamma Patch to investigate underwater obstructions. MATERIALS TESTING LABORATORY 242. Tests on building and engineering materials showed a considerable increase, both in number and scope. The number of tests carried out totalled 19,700 compared with 13,300 during the previous year. Details are as follows: No. of Tests (1) Concrete: compressive and flexural strength and chemical analysis 9,686 (2) Cement: physical properties 636 (3) Aggregates: physical properties and purity 2,684 (4) Metals: steel plates and bars for tensile strength and other tests 2,067 (5) Bitumen and bituminous mixtures 1,127 (6) Soils: classification, gradation, compaction, etc. 3,362 (7) Miscellaneous: including strength and other physical tests on hollow tiles, floor tiles, precast blocks, bricks, woodwool boards and plywood, and the calibration of pressure gauges 138 243. Of these, 920 were on behalf of private architects, contractors and building material suppliers. 244. Measurement of the temperature changes in experimental road slabs continued, but as the winter tended to be mild it will be necessary to continue these to gather more information before any conclusions can be reached. 245. The acquisition of additional equipment increased the capacity of the Laboratory for triaxial compression and California Bearing Ratio tests and the analysis of bituminous materials. New apparatus was installed for testing the hydraulic strength of pipes, the workability of lime plaster and the impact value of aggregates. 50 Page 50
Baseline (Original)
Rock, Ngau Tau Kok, Whampoa Docks, Ap Lei Chau, Quarry Bay, To Kwa Wan and Royal Naval Basin North Arm. (8) Sounding surveys before and after dredging at all nullah outfalls inside the harbour. (9) Surveys of foreshore and high water mark at Sham Tseng, Tsing Yi. Aberdeen, Staunton Creek, Ngau Chi Wan and near Rennie's Mili Village, in connexion with the gazetting of reclamations. (10) Progress surveys on public spoil dumps at Hung Hom, Cheung Sha Wan, Kwun Tong and Sandy Bay, and the Gin Drinker's Bay city refuse dump. (11) Setting out works for marine bores at Central Reclamation, Lai Chi Chong, Sham Chung, Ping Chau (Mirs Bay), High Island, Silver Mine Bay, Aberdeen, North Point and Lai Chi Kok. (12) Echo sounding surveys at Waglan Island and Lamma Patch to inves- tigate underwater obstructions. MATERIALS TESTING LABORATORY 242. Tests on building and engineering materials showed a consider- able increase, both in number and scope. The number of tests carried out totalled 19,700 compared with 13,300 during the previous year. Details are as follows: No. of Tests (1) Concrete: compressive and flexural strength and chemical analysis 9,686 (2) Cement: physical properties .636 (3) Aggregates: physical properties and purity 2,684 (4) Metals: steel plates and bars for tensile strength and other tests (5) Bitumen and bituminous mixtures 2,067 1,127 (6) Soils: classification, gradation, compaction, etc. 3,362 (7) Miscellaneous: including strength and other physical tests on hollow tiles, floor tiles, precast blocks, bricks, woodwool boards and plywood, and the calibration of pressure gauges 138 243. Of these, 920 were on behalf of private architects, contractors and building material suppliers. 244. Measurement of the temperature changes in experimental road slabs continued, but as the winter tended to be mild it will be necessary to continue these to gather more information before any conclusions can be reached. 245. The acquisition of additional equipment increased the capacity of the Laboratory for triaxial compression and California Bearing Ratio tests and the analysis of bituminous materials. New apparatus was installed for testing the hydraulic strength of pipes, the workability of lime plaster and the impact value of aggregates. 50 Pa P
2026-05-11 21:13:43 · Baseline
View content

Rock, Ngau Tau Kok, Whampoa Docks, Ap Lei Chau, Quarry Bay, To Kwa Wan and Royal Naval Basin North Arm.

(8) Sounding surveys before and after dredging at all nullah outfalls

inside the harbour.

(9) Surveys of foreshore and high water mark at Sham Tseng, Tsing Yi. Aberdeen, Staunton Creek, Ngau Chi Wan and near Rennie's Mili Village, in connexion with the gazetting of reclamations.

(10) Progress surveys on public spoil dumps at Hung Hom, Cheung Sha Wan, Kwun Tong and Sandy Bay, and the Gin Drinker's Bay city refuse dump.

(11) Setting out works for marine bores at Central Reclamation, Lai Chi Chong, Sham Chung, Ping Chau (Mirs Bay), High Island, Silver Mine Bay, Aberdeen, North Point and Lai Chi Kok.

(12) Echo sounding surveys at Waglan Island and Lamma Patch to inves-

tigate underwater obstructions.

MATERIALS TESTING LABORATORY

242. Tests on building and engineering materials showed a consider- able increase, both in number and scope. The number of tests carried out totalled 19,700 compared with 13,300 during the previous year.

Details are as follows:

No. of

Tests

(1) Concrete: compressive and flexural strength and chemical

analysis

9,686

(2) Cement: physical properties

.636

(3) Aggregates: physical properties and purity

2,684

(4) Metals: steel plates and bars for tensile strength and other tests (5) Bitumen and bituminous mixtures

2,067

1,127

(6) Soils: classification, gradation, compaction, etc.

3,362

(7) Miscellaneous: including strength and other physical tests on hollow tiles, floor tiles, precast blocks, bricks, woodwool boards and plywood, and the calibration of pressure gauges

138

243. Of these, 920 were on behalf of private architects, contractors and building material suppliers.

244. Measurement of the temperature changes in experimental road slabs continued, but as the winter tended to be mild it will be necessary to continue these to gather more information before any conclusions can be reached.

245. The acquisition of additional equipment increased the capacity of the Laboratory for triaxial compression and California Bearing Ratio tests and the analysis of bituminous materials. New apparatus was installed for testing the hydraulic strength of pipes, the workability of lime plaster and the impact value of aggregates.

50

Pa

P

Comments

Approved members can add comments, bookmarks, and private notes.

No comments yet.

Private Research Note

Private notes are available after approval.