1964_GASHOLDERS_EXAMINATION_REGULATIONS — Page 3

HK Historical Laws 香港歷史法例 All AI Reviewed

1980 Ed.]

Gasholders Examination Regulations

[CAP. 54

A 3

[Subsidiary]

10. A proprietor who contravenes regulation 3, 4, 5, 6(2) or Penalties. 7, or fails to carry out any requirement under regulation 8(b), shall be guilty of an offence and shall be liable on conviction to a fine of $50,000.

SCHEDULE

FORM

ANNUAL GASHOLDER INSPECTION AND MAINTENANCE RECORD WATER-SEALED GASHOLDER

Name of proprietor:

Gasholder number:

Gas stored:

Built in (date):

by:

Type (i.e. column, spiral or rope guided):

Capacity (exclusive of crown):

Lifts-Diameter and depth of, and pressure thrown by each lift:

Guide framing-Construction:

Crown-Rise:

Number and Type of Manholes:

Position and Number of Gas and Air Vents:

Sheets-Thickness of crown sheets:

Thickness of side sheets:

Cups and grips-Size and construction:

Top Curb and Crown Framing:

Type of Ladder:

Tank-Diameter:

Depth:

Construction:

Position in relation to ground level:

Rest Blocks:

Number:

Size:

Material used for construction of-

(a) Gasholder:

(b) Tank:

Inlet and Outlet Connexions-Size:

Date of inspection:

Inspection made by:

Government

Party

1. Framing:

Condition of-

(a) Columns.

(b) Girders

Position of each:

Together or separated:

(c) Junction of girders and columns.

(d) Wind bracing.

(e) Ladder or staircase and handrail.

[reg. 4.]

L.N. 55/80.

1988340

Edit History

2026-05-04 18:37:54 · NVIDIA / meta/llama-4-maverick-17b-128e-instruct
Live
View comparison
AI Proofread
1980 Ed.] Gasholders Examination Regulations [CAP. 54 A 3 [Subsidiary] 10. A proprietor who contravenes regulation 3, 4, 5, 6(2) or Penalties. 7, or fails to carry out any requirement under regulation 8(b), shall be guilty of an offence and shall be liable on conviction to a fine of $50,000. SCHEDULE FORM ANNUAL GASHOLDER INSPECTION AND MAINTENANCE RECORD WATER-SEALED GASHOLDER Name of proprietor: Gasholder number: Gas stored: Built in (date): by: Type (i.e. column, spiral or rope guided): Capacity (exclusive of crown): Lifts-Diameter and depth of, and pressure thrown by each lift: Guide framing-Construction: Crown-Rise: Number and Type of Manholes: Position and Number of Gas and Air Vents: Sheets-Thickness of crown sheets: Thickness of side sheets: Cups and grips-Size and construction: Top Curb and Crown Framing: Type of Ladder: Tank-Diameter: Depth: Construction: Position in relation to ground level: Rest Blocks: Number: Size: Material used for construction of- (a) Gasholder: (b) Tank: Inlet and Outlet Connexions-Size: Date of inspection: Inspection made by: Government Party 1. Framing: Condition of- (a) Columns. (b) Girders Position of each: Together or separated: (c) Junction of girders and columns. (d) Wind bracing. (e) Ladder or staircase and handrail. [reg. 4.] L.N. 55/80. 1988340
Baseline (Original)
1980 Ed.] Gasholders Examination Regulations [CAP. 54 A 3 [Subsidiary] 10. A proprietor who contravenes regulation 3, 4, 5, 6(2) or Penalties. 7, or fails to carry out any requirement under regulation 8(b), shall be guilty of an offence and shall be liable on conviction to a fine of $50,000. SCHEDULE FORM ANNUAL GASHOLDER INSPECTION AND MAINTENANCE RECORD WATER-SEALED GASHOLDER Name of proprietor: Gasholder number: Gas stored: Built in (date): by: Type (i.e. column, spiral or rope guided): Capacity (exclusive of crown): Lifts-Diameter and depth of, and pressure thrown by each lift: Guide framing-Construction: Crown-Rise: Number and Type of Manholes: Position and Number of Gas and Air Vents: Sheets-Thickness of crown sheets: Thickness of side sheets: Cups and grips-Size and construction: Top Curb and Crown Framing: Type of Ladder: Tank-Diameter: Depth: Construction: Position in relation to ground level: Rest Blocks: Number: Size: Material used for construction of- (a) Gasholder: (b) Tank: Inlet and Outlet Connexions-Size: Date of inspection: Inspection made by: Governm Prity 1. Framing: Condition of- (a) Columns. (b) Girders Position of each: Together or separated: (c) Junction of girders and columns. (d) Wind bracing. (e) Ladder or staircase and handrail. [reg. 4.] L.N. 55/80. Stof 1988340
2026-05-04 18:37:54 · Baseline
View content

1980 Ed.]

Gasholders Examination Regulations

[CAP. 54

A 3

[Subsidiary]

10. A proprietor who contravenes regulation 3, 4, 5, 6(2) or Penalties. 7, or fails to carry out any requirement under regulation 8(b), shall be guilty of an offence and shall be liable on conviction to a fine of $50,000.

SCHEDULE

FORM

ANNUAL GASHOLDER INSPECTION AND MAINTENANCE RECORD WATER-SEALED GASHOLDER

Name of proprietor:

Gasholder number:

Gas stored:

Built in (date):

by:

Type (i.e. column, spiral or rope guided):

Capacity (exclusive of crown):

Lifts-Diameter and depth of, and pressure thrown by each lift:

Guide framing-Construction:

Crown-Rise:

Number and Type of Manholes:

Position and Number of Gas and Air Vents:

Sheets-Thickness of crown sheets:

Thickness of side sheets:

Cups and grips-Size and construction:

Top Curb and Crown Framing:

Type of Ladder:

Tank-Diameter:

Depth:

Construction:

Position in relation to ground level:

Rest Blocks:

Number:

Size:

Material used for construction of-

(a) Gasholder:

(b) Tank:

Inlet and Outlet Connexions-Size:

Date of inspection:

Inspection made by:

Governm

Prity

1. Framing:

Condition of-

(a) Columns.

(b) Girders

Position of each:

Together or separated:

(c) Junction of girders and columns.

(d) Wind bracing.

(e) Ladder or staircase and handrail.

[reg. 4.]

L.N. 55/80.

Stof 1988340

Comments

Approved members can add comments, bookmarks, and private notes.

No comments yet.

Private Research Note

Private notes are available after approval.