SCHEDULE OF REQUIREMENTS

POST: CONSULATE-GENERAL HONG KONG

SCHEME: NEW OFFICES

DATE: JANUARY 1994

SECTION

OFFICER OR

NO

GRADE

FUNCTION

OF

CLASSI- FICATION

NETT

AREA

STAFF

m2

(1)

(2)

(3)

(4)

(5)

(6)

(5)

Chief

Security | 1

CSO

U/C

14.0

Officer

(6)

Security Office

4(Shift

S03s

U/C

17.0

Duties)

(7)

Equipment Store

(8)

Security Officers

(9)

Rest Room

Interview/ Meeting Room

H. GATEHOUSE

U/C

5.5

U/C

17.0

u/c

18.5

(1)

Security 1-2

Contract

U/C

11.0

Reception/

Guardroom

(2)

Site

Pedestrian

U/C

Entrance

REMARKS

(7)

Locate adjacent to G 2/3 with a view into G4. Allows space for security monitoring and X-ray equipment.

Sole access via G(6).

Room should be sound proof

Provide facilities as per "sleeping watches accommodation standards; either provide en suite wc and shower or locate near to such facilities.

to

G4.

Locate adjacent

Provide separate accesses from G4 and staff corridor. Door from G4 to be controlled from G2/3 by an electronic lock: the door to staff circulation should be fitted with a PBCL.

11.0

Specifications are concrete walls with B/R glass to give vision all round and into entrance area and vehicle inspection lock. Provide 2 speech units and document passing facilities.

Adjacent to guard room with secure screens to front and rear, each with electronic controlled pedestrian gate. Provide space for metal arch detection unit and wand search area. Bell push externally to guard room.

(4)

Guard's WC

(5)

Vehicle Inspection Lock

U/C

3.0

Provide WHB

U/C

As

Railing

necessary

lockable

type double gate to secure perimeter,

onto barriered internally leading section of access road immediately inside gate

162.0 sufficient to hold a single small truck.

Internally provide a manually operated lift-up

[+4.5] anti-crash barrier.

1. STORE ROOMS (TO BE LOCATED IN BASEMENT, IF POSSIBLE, UNLESS INDICATED OTHERWISE WITH EASY VEHICLE AREA)

(1)

Domestic equipment

(2)

Stationery

(3)

Furniture and

General

HONGKONG.SOR

U/C

14.0

If suitable space available can also be located in or near to section F.

U/C

46.5

01

30

H

U/C

93.0

If additional space required either locate in any surplus basement space outhouse in 153.5 warehouse.

ог

Comments