TNAG-1613-FCO40-2221-Executive-Council-of-Hong-Kong-memoranda-and-minutes-of-meet-1987 — Page 237

FCO40 Hong Kong Department Records 聯邦事務部香港部檔案 All

Distance

(ul)

-

19

-

Table 5

Conversion Factors to Obtain the Predicted Noise Level from Sound

Power Levels at Given Distances

Correction

(dB(A))

Distance

(m)

Correction

(dB(A))

0

8

53 to 59

43

1

8

60 to 66

44

2

14

67 to 74

45

3

18

75 to 83

46

4

20

84 to 93

47

5

22

94 to 105

48

6

24

106 to 118

49

7

25

119 to 132

50

8

26

11

133 to 148

51

9

27

149 to 166

52

10

28

167 to 187

53

11

29

188 to 210

54

12

30

211 to 235

55

13

30

236 to 264

56

14

31

265 to 296

57

15 to 16

32

297 to 333

58

17 to 18

33

||

334 to 373

59

19 to 21

34

374 to 419

60

22 to 23

35

420 to 470

61

24 to 26

36

471 to 527

62

27 to 29

37

11

528 to 592

63

30 to 33

38

593 to 664

64

34 to 37

39

665 to 745

65

38 to 41

40

11

746 to 836

66

42 to 47

41

837 to 938

67

48 to 52

42

939 to 1000

68

For the purpose of determining the correction to be used for

converting from sound power level at the source to the PNL at the NSR,

the distance from the source position to the NSR shall be determined to

the nearest whole metre, with values of 0.5 or more being rounded

upwards.

This table is only valid for distances of up to 1 000 m. For

distances greater than 1 000 m the Authority shall calculate appropriate

correction factors having regard to standard acoustical principles and

practices.