An additional positive correction of 3dB(A) may be applied to

the PNL in cases where the Authority considers that noise levels at the

NSR will be increased due to the confined or reverberant nature of the

immediate locality of the construction site and the NSR.

2.12 Step 12

Corrected Noise Level (CNL) at the Noise Sensitive

Receiver (NSR)

The corrections obtained in Steps 10 and 11 shall be applied to

the PNL obtained in Step 9 to give the CNL at the NSR.

2.13 Step 13 - Construction Noise Permit (CNP) Issuing Procedure

The CNL at the NSR obtained in Step 12 shall be compared with

the ANL obtained in Step 6. If the CNL is equal to or less than the ANL

the CNP may be issued. If the CNL is greater than the ANL the CNP shall

not be issued unless the application is a special case as defined in

Section 3. The procedures detailed in Section 3 shall then be followed.

When giving consideration to the renewal of CNPs pursuant to

Section 9 of the Ordinance the Authority may impose additional conditions

or may refuse to renew a CNP having regard to complaints received and

other relevant factors, notwithstanding the procedures and guidelines

detailed in Steps 1 to 12.

To assist in enforcement procedures the Authority may include

as a condition for all CNPs a requirement for the CNP applicant to ensure

that each item of PME which is permitted to be used on the construction

site is, at the time of its use, labelled in a legible and conspicuous.

manner with the appropriate identification code as shown in Table 3. For

items not given in Table 3 the identification code to be used shall be as

specified by the Authority in the CNP.