temperature increase resulting from the most extreme accident. It
to tornados,
and earthquakes
can
stand
up
other
natural
disasters. It can stand up to aerial bombardment or being crashed
upon by a jet aeroplane.
the worst possible scenario, the containment
In
would
be able to contain the radioactive
building
materials
within itself, ensuring that the release of radioactive materials
into the environment remains within permitted limits.
MEASURES FOR DEFENCE IN DEPTH AT THE NUCLEAR POWER STATION
Quality control system
1.
2.
3.
Design examination and ratification system
Testing and acceptance system for components and equipment
Assembly testing system
4. Operational training system
Automatic emergency shut-down system
1.
Safety rods
2. Boric acid water system
Standby installations
Secondary electricity supply
Emergency electricity source
Isolation of the containment building and safeguards system
1. Automatic isolation system
Automatic spraying system
2.
3.
Air purification system
4.
Dehydrogenizing system