No_6_1959 — Page 46

Far East Builder 遠東建築雜誌 All

at

dependently controlled. Further in- ternal partitioning flexibility is gain- ed by using air-conditioning outlet grills on a grid of 10 ft. x 12 ft. 6 in. and fibrous telephone ducts. 10 ft. centres embedded in a crete screed and using a suspended ceiling of perforated steel stove en- amelled pans containing absorbents. which are easily detachable.

con-

The offices are well-lit and the steel windows are protected by hori zontal and vertical bush-hammered 3 in. concrete fins free standing from the infil which is faced steel section containing clear decorated coloured glass. orientation is incorrect, venetian

with and As the

blinds are

built into a periphery channel in the ceiling.

The structural construction is of reinforced concrete throughout. The multi-storey structure contains trans- verse beams at 20 ft. centres with openings in the beams for the longitudinal air-condition duct work and small secondary longitudinal beams at 5 ft. centres supporting the 2 in. thick concrete floor. The infil panels are of either hollow con- crete block or light weight concrete.

The finish to the canteen is mosaic tile and wood parquet floor with decorated plastic to walls. The of fices have vinyl floors with a cir-

culation area and stairs of mosaic.

The Post Office contains terrazzo. wood parquet, vinyl and decorated inter-play tiles, thick panelling. anodised aluminium facings and louvres. All main doors and screens are of aluminium.

is

An interesting feature is that though the Post Office concourse is not air-conditioned. forced draft ducted into the area to give maxi- mum ventilation.

Mr.

The quantity surveyor was A. D. Bridges, A.R.I.C.S. Messrs. A.J. Broom, A.M.I. Struct. E., and Thean Swee Ching, Grad. I. Struct. E.. were the structural engineers.

X

44

O

3

Air Condition Plast Room

Deci

HALL

SPA

13 20 25

Typical floor plan.

Female Lov

Duct

| Machine Room

For Lifts

Γ

Nos Meille

Kitchen

Servery

Start

Stora

CANTEE N

FL

Sorvary

20 25

Canteen floor plan.

x

Mutia

Kitchen

estrector's

Office

THE HONG KONG & FAR EAST BUILDER

-

VOLUME 14, NUMBER F

Comments

Approved members can add comments, bookmarks, and private notes.

No comments yet.

Private Research Note