AnnualReport-1914 — Page 170

Administrative Reports 行政報告書 All AI Reviewed

E 12

Scales with more distinct lines have been ordered. On the same date the counting comb was removed and a new micrometer head fitted for recording the revolutions of the screw; a worm wheel on the head operating a graduated dial.

Clocks. The daily losing rate of the sidereal Standard clock (Dent 39741) varied from +0 s .60 on January 3, to -1 s .01 on several days in the summer. At the former rate the barometric pressure was 30.24, and the temperature of the clock room 60°.9. At the latter rate the barometric pressure varied from 29.39 to 29.65 and the temperature from 82° to 85°. The excess of the observed rate over the calculated rate, after cloudy periods is given below:

Edit History

2026-05-06 08:19:19 · NVIDIA / meta/llama-4-maverick-17b-128e-instruct
Live
View comparison
AI Proofread
E 12 Scales with more distinct lines have been ordered. On the same date the counting comb was removed and a new micrometer head fitted for recording the revolutions of the screw; a worm wheel on the head operating a graduated dial. Clocks. The daily losing rate of the sidereal Standard clock (Dent 39741) varied from +0 s .60 on January 3, to -1 s .01 on several days in the summer. At the former rate the barometric pressure was 30.24, and the temperature of the clock room 60°.9. At the latter rate the barometric pressure varied from 29.39 to 29.65 and the temperature from 82° to 85°. The excess of the observed rate over the calculated rate, after cloudy periods is given below:
Baseline (Original)
E 12 Scales with more distinct lines have been ordered. On the same date the counting comb was removed and a new micrometer head fitted for recording the revolutions of the screw; a worm wheel on the head operating a graduated dial. Clocks. The daily losing rate of the sidereal Standard clock (Dent 39741) varied from +0*60 on January 3, to -101 on several days in the summer. At the former rate the barometric pressure was 30-24, and the temperature of the clock room 60°-9. At the latter rate the barometric pressure varied from 29-39 to 29.65 and the temperature from 82° to 85°. The excess of the observed over the calculated rate, after cloudy periods is given below:-~-
2026-05-06 08:19:19 · Baseline
View content

E 12

Scales with more distinct lines have been ordered. On the same date the counting comb was removed and a new micrometer head fitted for recording the revolutions of the screw; a worm wheel on the head operating a graduated dial.

Clocks. The daily losing rate of the sidereal Standard clock (Dent 39741) varied from +0*60 on January 3, to -101 on several days in the summer. At the former rate the barometric pressure was 30-24, and the temperature of the clock room 60°-9. At the latter rate the barometric pressure varied from 29-39 to 29.65 and the temperature from 82° to 85°. The excess of the observed

over the calculated rate, after cloudy periods is given below:-~-

Comments

Approved members can add comments, bookmarks, and private notes.

No comments yet.

Private Research Note

Private notes are available after approval.